GPU cards promise lower CT scan radiation

Posted: 06 Aug 2010     Print Version  Bookmark and Share

Keywords:CT scan  GPU cards  X-ray 

University of California, San Diego (UCSD) researchers have formulated CT reconstruction algorithm for graphic processing unit (GPU) platforms to process X-ray data which can result into lower CT scan radiation. This new approach promises to lower by a factor of ten or more the amount of radiation patients receive during cone beam CT scans as per the researchers.

Cone beam CT plays an essential role in image-guided radiation therapy (IGRT), for cancer treatment. IGRT uses repeated scans during a course of radiation therapy to precisely target tumours and minimise radiation damage in surrounding tissue. Though IGRT has improved outcomes, the large cumulative radiation dose from the repeated scans has raised concerns among physicians and patients.

Reducing the total number of X-ray projections and the mAs level per projection (by tuning down the X-ray generator pulse rate, pulse duration and/or current) during a CT scan can help minimise patient's exposure to radiation, but the change results in noisy, mathematically incomplete data that takes hours to process using the current iterative reconstruction approaches. Because CBCT is mainly used for treatment setup while patients are in the treatment position, fast reconstruction is a requirement, explains lead author Xun Jia, a UCSD postdoctoral fellow.

Based on recent advances in the field of compressed sensing, Jia and his colleagues developed an innovative CT reconstruction algorithm for graphic processing unit (GPU) platforms. The GPU processes data in parallel— increasing computational efficiency and making it possible to reconstruct a cone beam CT scan in about two minutes. (Modern GPU cards were originally designed to power 3D computer graphics, especially for video games.)

With only 20 to 40 total number of X-ray projections and 0.1mAs per projection, the team achieved images clear enough for image-guided radiation therapy. The reconstruction time ranged from 77 to 130s on an NVIDIA Tesla C1060 GPU card, depending on the number of projections— an estimated 100 times faster than similar iterative reconstruction approaches, says Jia.

Compared to the currently widely used scanning protocol of about 360 projections with 0.4mAs per projection, Jia says the new processing method resulted in 36 to 72 times less radiation exposure for patients.

"With our technique, we can reconstruct cone beam CT images with only a few projections— 40 in most cases— and lower mAs levels," he says. "This considerably lowered the radiation dose."

The reconstruction algorithm is part of the UCSD group's effort to develop a series of GPU-based low dose technologies for CT scans.

"In my mind, the most interesting and compelling possibilities of this technique are beyond cancer radiotherapy," says Steve Jiang, senior author of the study and a UCSD associate professor of radiation oncology.

"CT dose has become a major concern of medical community. For each year's use of today's scanning technology, the resulting cancers could cause about 14,500 deaths.

"Our work, when extended from cancer radiotherapy to general diagnostic imaging, may provide a unique solution to solve this problem by reducing the CT dose per scan by a factor of 10 or more," says Jiang.





Comment on "GPU cards promise lower CT scan radi..."
Comments:  
*  You can enter [0] more charecters.
*Verify code:
 
 
Webinars

Seminars

Visit Asia Webinars to learn about the latest in technology and get practical design tips.

 

Go to top             Connect on Facebook      Follow us on Twitter      Follow us on Orkut

 
Back to Top