Implementing thermocouple interface with MSP430F5529 MCU

Posted: 11 Oct 2011     Print Version  Bookmark and Share

Keywords:thermocouple  microcontroller 

Here's discussion on how to implement a thermocouple interface. The thermocouple circuit interfaces with the MSP430F5529 microcontroller from Texas Instruments. The MSP430F5529 is a 16bit microcontroller with 20bit addressing and an integrated 12bit analogue-to-digital converter (ADC). The integrated ADC is used to convert the thermocouple voltage into digital values, and the MSP430F5529 CPU is used to convert the digital values into temperature and store them in memory. A complete code set accompanies this document. For this document, a Type K thermocouple is used, and the measured temperature range is limited to 0°C to 100°C.

View the PDF document for more information.

Originally published by Texas Instruments at www.ti.com as "Implementing a Thermocouple Interface With ADC12_A".