NI expands DAQ series with 12 isolated multifunction devices

Posted: 18 Aug 2006     Print Version  Bookmark and Share

Keywords:National Instruments  12  M and S Series  data acquisition 

National Instruments has announced 12 isolated M and S Series multifunction data acquisition (DAQ) devices. These devices combine the safety of isolation with the high-performance timing, amplification and calibration technologies of existing M Series DAQ devices for increased accuracy. Built-in isolation increases the safety of data acquisition devices and eliminates common problems that can ruin measurement accuracy. The new multifunction devices offer 16-bit accuracy, 250KSps sampling rates, ±10 V or ±20mA analogue inputs, ±10 V or 0-20mA analogue outputs and 5 V TTL/CMOS or 24V digital inputs and outputs.

These isolated M and S Series devices offer channel-to-channel or bank isolation with 1,950Vdc/1,400Vrms transient withstand for5 s to a PCI bus, which protects expensive equipment, the user and data from hazardous voltage spikes, transient signals and electrical noise. Isolation works by electrically separating the circuit's front end, where hazardous voltages can exist, from the rest of the data acquisition system. Isolation is especially important when taking measurements from sensors in the proximity of wall power, large motors, high-voltage switches or other high-voltage lines.

Isolated M and S Series devices also reject common-mode voltages and prevent ground loops from forming, eliminating two common problems for data acquisition system users. High common-mode voltages can make it impossible to measure the signal in a non-isolated data acquisition system and can even damage the system. The new isolated M and S Series devices can measure from sensors with the signal plus common-mode voltages of up to 60 V. Ground loops, which occur when there is a difference between the ground voltages of the measurement system and the signal being measured, can result in high currents flowing between the two grounds and can damage equipment and ruin accuracy.




Comment on "NI expands DAQ series with 12 isolat..."
Comments:  
*  You can enter [0] more charecters.
*Verify code:
 
 
Webinars

Seminars

Visit Asia Webinars to learn about the latest in technology and get practical design tips.

 

Go to top             Connect on Facebook      Follow us on Twitter      Follow us on Orkut

 
Back to Top